titanium mesh cage(tmc) Search Results


90
DePuy Synthes harms titanium mesh cages
Harms Titanium Mesh Cages, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/harms titanium mesh cages/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
harms titanium mesh cages - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Technical Manufacturing Company titanium mesh cage(tmc)
Titanium Mesh Cage(Tmc), supplied by Technical Manufacturing Company, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cage(tmc)/product/Technical Manufacturing Company
Average 90 stars, based on 1 article reviews
titanium mesh cage(tmc) - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
DePuy Synthes cylindrical (spinal) titanium mesh cage
Cylindrical (Spinal) Titanium Mesh Cage, supplied by DePuy Synthes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cylindrical (spinal) titanium mesh cage/product/DePuy Synthes
Average 90 stars, based on 1 article reviews
cylindrical (spinal) titanium mesh cage - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Stryker titanium mesh cage stryker v-boss ® cage
Titanium Mesh Cage Stryker V Boss ® Cage, supplied by Stryker, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cage stryker v-boss ® cage/product/Stryker
Average 90 stars, based on 1 article reviews
titanium mesh cage stryker v-boss ® cage - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Dassault Systemes titanium mesh cage (ntmc)
Titanium Mesh Cage (Ntmc), supplied by Dassault Systemes, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cage (ntmc)/product/Dassault Systemes
Average 90 stars, based on 1 article reviews
titanium mesh cage (ntmc) - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Motech Industries cylindrical (spinal) titanium mesh cages depuy
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Cylindrical (Spinal) Titanium Mesh Cages Depuy, supplied by Motech Industries, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cylindrical (spinal) titanium mesh cages depuy/product/Motech Industries
Average 90 stars, based on 1 article reviews
cylindrical (spinal) titanium mesh cages depuy - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Medtronic Sofamor Danek pyramesh titanium mesh cage
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Pyramesh Titanium Mesh Cage, supplied by Medtronic Sofamor Danek, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pyramesh titanium mesh cage/product/Medtronic Sofamor Danek
Average 90 stars, based on 1 article reviews
pyramesh titanium mesh cage - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Globus Medical titanium mesh cage
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Titanium Mesh Cage, supplied by Globus Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cage/product/Globus Medical
Average 90 stars, based on 1 article reviews
titanium mesh cage - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Alphatec Spine expandable titanium mesh cage (osseofix® system)
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Expandable Titanium Mesh Cage (Osseofix® System), supplied by Alphatec Spine, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/expandable titanium mesh cage (osseofix® system)/product/Alphatec Spine
Average 90 stars, based on 1 article reviews
expandable titanium mesh cage (osseofix® system) - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Janssen titanium mesh cage
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Titanium Mesh Cage, supplied by Janssen, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cage/product/Janssen
Average 90 stars, based on 1 article reviews
titanium mesh cage - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
TransOral Pharmaceuticals titanium mesh cage
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Titanium Mesh Cage, supplied by TransOral Pharmaceuticals, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cage/product/TransOral Pharmaceuticals
Average 90 stars, based on 1 article reviews
titanium mesh cage - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Sofamor Danek Group titanium mesh cages pyramesh
First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a <t>cylindrical</t> (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.
Titanium Mesh Cages Pyramesh, supplied by Sofamor Danek Group, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/titanium mesh cages pyramesh/product/Sofamor Danek Group
Average 90 stars, based on 1 article reviews
titanium mesh cages pyramesh - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a cylindrical (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.

Journal: Journal of Functional Biomaterials

Article Title: The Concept of Scaffold-Guided Bone Regeneration for the Treatment of Long Bone Defects: Current Clinical Application and Future Perspective

doi: 10.3390/jfb14070341

Figure Lengend Snippet: First case report from 1999 by Cobos et al. on the treatment of a patient (34-year-old) with post-traumatic segmental defect of the tibia (8.5 cm) with a cylindrical (spinal) titanium mesh cage in combination with cancellous bone allograft and demineralized bone matrix putty (Grafton) stabilized with an intramedullary nail. The titanium mesh cage was trimmed to 9 cm (diameter 2.2 cm) to fit the defect size and packed with allograft prior to implantation ( A ). Posterolateral callus consolidation around the cage on X-ray (views: ( B1 ): anterior–posterior; ( B2 ): lateral) 12 months post-reconstruction. Standing patient ( C1 ) and standing on the operated limb ( C2 ) at one-year follow-up. Adapted from Ref. , reproduced with permission from John Wiley & Sons, Inc.

Article Snippet: The first clinical application of cylindrical (spinal) titanium mesh cages (DePuy Motech, Warsaw, IN, USA) was described in 1999 for combination with cancellous bone allograft and demineralized bone matrix for the reconstruction of posttraumatic diaphyseal tibial defects in two patients [ ].

Techniques:

Exemplary challenges and failures in the use of cylindrical titanium mesh cage implants for bone defects. X-ray of a 29-year-old male with a segmental tibial defect and treatment for definitive fixation with an intramedullary nail and cylindrical titanium mesh cage (DePuy Synthes) ( A ). The asterisks in A1 highlight the graft material four months after grafting, which is packed into and on the outer surface of the cylindrical mesh implant. After 90 months, there is stagnation in the bony consolidation on the surface of the implant (asterisks) compared to plain radiography findings after four months and, in particular, no evidence of a bony structure within the cylindrical titanium mesh cage (triangles) (( B1) : anterior–posterior; ( B2 ): lateral). Patient-specific titanium mesh implant (DePuy Synthes) packed with RIA system graft material implanted to treat a femoral defect ( C ). Twenty-eight months after implantation, a subtle but distinctive callus formed bridging the defect on the implant surface (( D ), asterisks indicating bone bridge). However, no bony consolidation was observed in the inner part of the titanium mesh. The triangles in D indicate that the mesh structure is radiolucent, which would not be possible if ABG remodelling and thus successful regeneration of the graft material of the RIA system had occurred. ( A , B ): reproduced from Supplement of Ref. , with permission from the British Editorial Society of Bone & Joint Surgery; ( C ): reproduced from Supplement of Ref. , reprinted with permission from American Association for the Advancement of Science (AAAS).

Journal: Journal of Functional Biomaterials

Article Title: The Concept of Scaffold-Guided Bone Regeneration for the Treatment of Long Bone Defects: Current Clinical Application and Future Perspective

doi: 10.3390/jfb14070341

Figure Lengend Snippet: Exemplary challenges and failures in the use of cylindrical titanium mesh cage implants for bone defects. X-ray of a 29-year-old male with a segmental tibial defect and treatment for definitive fixation with an intramedullary nail and cylindrical titanium mesh cage (DePuy Synthes) ( A ). The asterisks in A1 highlight the graft material four months after grafting, which is packed into and on the outer surface of the cylindrical mesh implant. After 90 months, there is stagnation in the bony consolidation on the surface of the implant (asterisks) compared to plain radiography findings after four months and, in particular, no evidence of a bony structure within the cylindrical titanium mesh cage (triangles) (( B1) : anterior–posterior; ( B2 ): lateral). Patient-specific titanium mesh implant (DePuy Synthes) packed with RIA system graft material implanted to treat a femoral defect ( C ). Twenty-eight months after implantation, a subtle but distinctive callus formed bridging the defect on the implant surface (( D ), asterisks indicating bone bridge). However, no bony consolidation was observed in the inner part of the titanium mesh. The triangles in D indicate that the mesh structure is radiolucent, which would not be possible if ABG remodelling and thus successful regeneration of the graft material of the RIA system had occurred. ( A , B ): reproduced from Supplement of Ref. , with permission from the British Editorial Society of Bone & Joint Surgery; ( C ): reproduced from Supplement of Ref. , reprinted with permission from American Association for the Advancement of Science (AAAS).

Article Snippet: The first clinical application of cylindrical (spinal) titanium mesh cages (DePuy Motech, Warsaw, IN, USA) was described in 1999 for combination with cancellous bone allograft and demineralized bone matrix for the reconstruction of posttraumatic diaphyseal tibial defects in two patients [ ].

Techniques: